![]() For outdoor installations, use a UL Listed weatherproof back box and seal the wire entry locations with silicone and provide a drain hole. An appropriate range is typically between 48 and 52 inches on center off the floor. Mounting height can vary depending on requirements. Mounting the Keypad The keypad is designed to be flush mounted using a standard UL Listed single-gang electrical box. The 2000e/eM keypads were evaluated by UL, in Wiegand Front End mode, for use only with the IEI Hub Max II and Hub MiniMax II products used in conjunction with the Wiegand Interface Module. The locking device and all inputs and outputs are connected to the control panel. The control panel maintains the users and programming options and makes all the access control decisions. ![]() When you enter a code on the keypad it is then sent to the control panel as Wiegand card data, depending on which format you've programmed it for. Wiegand Front End Mode: In Wiegand Front End mode, a separate Wiegand Access Control panel is required. The 2000e/eM keypads were evaluated by UL, in Secured Series Front End mode, for use only with the IEI Hub Max II and Hub MiniMax II products. The locking device and all inputs and outputs are connected to the controller. ![]() The IEI Secured Series Controller maintains the users and programming options and makes all the access control decisions. Secured Series Front End Mode: In Secured Series Front End mode, an IEI Secured Series Controller is required. The lock and all other inputs and outputs are connected directly to the keypad. In this mode, all the users and other programming options are maintained within the keypad and no additional controller is required. Standalone Mode: By default, the keypad is programmed for Standalone Mode. Refer to the programming section for details about selecting each mode. Below is a brief explanation of each mode. Keypad Operating Modes The 2000e/2000eM keypad has three operating modes: Standalone Mode, Secured Series Front End Mode and Wiegand Front End Mode. End User: Please contact your service company. Questions can also be submitted through our website at. – 22 AWG Firmware Version 1.0x (“1” is the major version “0” is the minor version “x” is a minor version, reserved for bug fixes, which is indicated with a letter, such as “a”.) Technical Support Service Company: To contact IEI’s Technical Support department, call 1- 80, Monday through Friday. Relay Contact Rating 2A 30VDC (Main & Aux) REX Input Normally Open Dry Contact Door Position Switch Input Normally Closed Dry Contact Mechanical Dimensions 4.50" H x 2.75" W x 0.60" D Environment Indoor or Outdoor Temperature Tolerance -31☏ to 151☏ (-35✬ to 66☌) Front End Cable Type Stranded and Shielded Front End Distance and Wire Gauge 1000 Ft. 2000 Series e/eM Style Keypad Installation and Programming Guide Models 2000e and 2000eM Specifications Parameter Specifications Voltage Requirements 10-30 VDC 12-24VAC Keypad Current Requirements (Max) VDC VAC 10V: 85mA 30V: 115mA 12V: 150mA 24V: 200mA Keypad with Output Expansion Module (2000- 8EX) Current Requirements (Max) VDC VAC 10V: 230mA 30V: 390mA 12V: 500mA 24V: 700mA Note: This is total maximum current including keypad and output module.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |